SANSURE Slan 96P

SANSURE Slan 96P

Location:France

orCall +33 (0)4 86 64 67 24

Description

YOM 07/2020 condition AS NEW used only 2 months for PCR COVID-19 tests, sold with PC and ready to work. Contact us for price. The SLAN-96P's dual 48/48 reaction blocks are controlled separately, as two independent instruments. With the SLAN-96P, two different tests can be tested simultaneously on a single instrument or a new test can be started while another is running. Product Performance Advanced fluorescence detection system - reliable, sensitive and calibration-free Unique side-capture signal collection technology improves fluorescence capture efficiency and eliminates signal noise, providing better detection sensitivity and smooth amplification curves; Improved optical system reduces instrument background noise, ensuring better reproducibility; long lasting high intensity LEDs that are reliable and maintenance free; Negligible optical background resulting in no background calibration required; Innovative optical light path design eliminating edge effect and giving uniform fluorescence intensity for each tube, no ROX reference calibration required; The instrument hardware automatically calculates the gain during operation. No gain adjustment is required; Professional optical filter combinations eliminate crosstalk between FAM, HEX, ROX and CY5 channels.NO crosstalk calibration required. Generates much faster accurate results in less than 50 minutes Based on the original SLAN system, the latest SLAN-96P has improved its thermal design with an ultra-fast heating/cooling rate of up to 4.5°C/s. Professional multiplex detection channels - true PCR 6plex real-time playback The SLAN-96P's 6 sets of excitation and emission filter combinations provide real-time playback capability by 6-color multiplexing; you will benefit from great flexibility in the choice of fluorescence dyes and detection format. Ideal approach to your HRM study - accurate, sensitive, no need for calibration complicated from temperature change Fast fluorescence detection mode completes genetic scanning in 30 minutes; Advanced hardware design and software algorithms generate an accurate date without the need for temperature offset calibration. Highlights Outstanding hardware and software design to ensure data repeatability and accuracy amplification Correlation coefficient: -0.999 ~ -1.000 Repeatability: CV<0.5% Sensitivity: detection of a single copy Linear range: 1-1010 High reliability: easy to distinguish the concentration difference between 1000 and 2000. Experimental data can be derived from a variety of formats, convenient access to the LIMS system.

Specifications

ManufacturerSANSURE
ModelSlan 96P
ConditionUsed
Stock Number1876856